Girard Tankless Water Heater Error Code E8
| | |

Girard Tankless Water Heater Error Code E8

The E8 error code on the Girard Tankless Water Heater indicates that the control board doesn’t see the pressure switch close. In other words, the control board fails to detect the air pressure switch for 7 seconds before ignition.  Here are the reasons for the error code E8 on Girard Tankless Water Heater:  Below, I…

Girard Tankless Water Heater Error Code E5
| | |

Girard Tankless Water Heater Error Code E5

Girard Tankless Water Heater Error Code E5 means blower motor failure. It means the control board defects no motor signal before ignition or during normal operation. This fault code will appear on the display because of a faulty motor or defective wire connections in the motor.  Other reasons that could cause the E5 code to…

Girard Tankless Water Heater Error Code E1
| | |

Girard Tankless Water Heater Error Code E1

Girard Tankless Water Heater Error Code E1 means ignition failure. This fault code tells you that the water heater tried to ignite twice but didn’t ignite. Due to one of the following reasons, the tankless unit will give an E1 code on the UCP:  I will walk you through every troubleshooting step to diagnose the…

Girard Tankless Water Heater Error Code E3
| | |

Girard Tankless Water Heater Error Code E3

Error code E3 on the Girard Tankless Water Heater indicates that the ECO gets tripped. When the output temperature exceeds 140 degrees during operation, it will trigger the ECO sensor. As a result, the tankless unit will go into the lockout mode and give an E3 code.  Because of these possible reasons below, the GSWH-2…

Fogatti Tankless Water Heater E8 Error Code
| |

Fogatti Tankless Water Heater E8 Error Code

Error code E8 on Fogatti RV Tankless Water Heater indicates wind pressure switch failure. The unit will constantly throw this fault code if:  To reset the error code, you must address and resolve those issues.  Fortunately, I am here to walk you through the troubleshooting steps to fix the problem.  So, let’s dive in.  Troubleshooting…

Fogatti Tankless Water Heater E6 Error Code
| |

Fogatti Tankless Water Heater E6 Error Code

Fogatti Tankless Water Heater E6 Error Code means overheating failure. The controller will flash this fault code when the water temperature remains above 176 degrees F for over 3 seconds.  Due to the following reasons, the error code E6 will appear on the display:  Below, I will show you how to reset the fault code…

Fogatti Tankless Water Heater E5 Error Code
| |

Fogatti Tankless Water Heater E5 Error Code

Fogatti Tankless Water Heater E5 Error Code means fan failure. The control board detects no fan signal during start-up or water heater operation. It occurs when:  Below, I will describe every troubleshooting step to detect the culprits and how you can fix this issue.  Without further ado, let’s scroll down.  Troubleshooting Fogatti Tankless Water Heater…

Fogatti RV Tankless Water Heater Error Code 1
| |

Fogatti RV Tankless Water Heater Error Code 1

Fogatti RV Tankless Water Heater Error Code E1 means ignition failure. Your RV Tankless Water Heater won’t ignite because of one of the following reasons:  Throughout this guideline, I will describe those issues and walk you through the troubleshooting steps to resolve them.  So, let’s dive in. Fogatti RV Tankless Water Heater Error Code E1…

Fogatti RV Tankless Water Heater Troubleshooting Codes
| |

Fogatti RV Tankless Water Heater Troubleshooting Codes

This is a complete guide on Fogatti RV Tankless Water Heater Troubleshooting Codes. You can learn about the meaning of each error code, what causes the error message to pop up, and how you can resolve them. So, keep reading till the end.  9 Common Fogatti RV Tankless Water Heater Troubleshooting Codes Here is the…